At present, LK-MC80SE is mostly installed at the outlet of small bag boxes on site in China, and is used for bag positioning and leak detection together with LK-MC80S4/5 of the discharge manifold. All control and analysis are processed in the DCS system.
In Europe, we also provide the Dibuge7.0 software analysis system, which works in conjunction with the on-site installation of LK-MC80SE and LK-MC80S4/5 to provide on-site analysis and operation. It brings convenience to the independent regional control and central monitoring of large factories and mines.
Based on years of domestic and international experience, we can provide different overall solutions for China Everbright customers.
● Bag leak detection switch
● Wide range ratio
● No signal drift
● High cost-effectiveness
● ATEX explosion-proof high temperature type optional
● Widely used in bag dust removal systems across various industries in China
Measurement medium: solid particles in the airflow
Medium size: diameter greater than 0.3 μ m
Measurement range: 0.1mg/m ² -1.0kg/m ²
Process conditions:
Temperature: up to 140 ℃ (300 ℃ optional)
Pressure: 200kPa (other details to be consulted with the manufacturer)
Airflow velocity: greater than 4m/s
Humidity: 95% RH (consult manufacturer for condensation)
Measurement principle: AC electrostatic induction principle
Damping time: 1-300S
Output signal: Two alarm limit outputs
Environmental temperature: -20 to+60 ℃
Probe material: 316 stainless steel
Shell: Aluminum
Protection level: IP65
Power supply: 12-24VDC
Power: 3W
Connection cable: 8-core (4 pairs) shielded cable
Process connection: 1/2 "NPT threaded connection
Weight: Approximately 0.7kg